Planning application details ref: 20218 Galway City Council

100%100% Complete (warning)

Planning Application: 20218 (Galway City Council)
File Number: 20218
Application Type: PERMISSION Planning Status: APPLICATION FINALISED
Received Date: 20/08/2020 Decision Due Date: 24/02/2022
Validated Date: 20/08/2020 Invalidated Date:
Further Info Requested: 13/10/2020 Further Info Received: 30/11/2021
Withdrawn Date: Extend Date:
Decision Type: Conditional Decision Date: 24/02/2022
Leave to Appeal: Appeal Date: 23/03/2022
Commenced Date: Submissions By: 10/02/2022

Applicant Details

Applicant name: Parosi Developments Ltd
Applicant Address:
Phone Number: Fax Number:
Corresp. Address:

Applicant Details


Proposed Development

Development Description: Permission is sought for the development which will consist of construction of an eight storey over basement, 186 no. bedroom hotel with below ground pool plant equipment, tank room, standby generator and pumping station (Gross Floor Area: c. 12,478sqm). The development includes for hotel uses on the ground floor including a reception area, lounge area, a restaurant, a bar, a lobby, toilet facilities, and back of house rooms. The ground floor also includes an LV switchroom, an MV switchroom, an ESB substation, a transformer/LV switchroom, a public entrance to the spa and spa facilities including a swimming pool, a whirlpool, a sauna/steam room, male and female changing rooms, and storage rooms. The first floor incorporates spa facilities including a treatment room, a studio, a gym, a lobby area, a storage area, 8 no. meeting rooms with associated reception area, an office, toilet facilities and a pantry. The upper floors incorporate 186 no. hotel bedrooms. The development also includes for a green roof, emergency fire escapes, an upgrade to the existing entrance/exit from the Business Park Campus, new guest vehicle entrance from the Business Park Campus to the north of the site, 2 no. new vehicle entrances from the west of the site, 153 no. car parking spaces, 3 no. set down spaces at the main entrance, service entrance layby to the west of the site, 28 no. cycle spaces, electrical vehicle charging spaces, pumping station kiosk, signage, associated landscaping and boundary treatments, and all other site development works and services ancillary to the proposed development
Development Address: Site 4, Briarhill Business Park, Bothar na dTreabh, in the townlands of Ballybrit and Doughiska, Galway
Architect Name: Location Key: BALLYBRIT
Electoral Division: Planner: Liam Blake
Social Housing Exempt: Plan Enforcement #:
IPC Licence Required: No Waste Licence Required: No
Protected Structure: No Protected Structure #:
Development Name:

Proposed Development


Comments

Significant Case Flag: Comments: CFI REQUESTED ON 1/9/21 AND NOT FPN. EXPIRY DATE FOR RECEIPT OF CFI = 30/11/2021

Decision

Decision Date: 24/02/2022 Manager Order: 744526
Decision Type: Conditional Number of Conditions: 22
Grant Date: Grant Managers Order #:
Section 47 Apply?: Part 5 Apply?:
Expiry Date:
Decision Description: Permission is sought for the development which will consist of construction of an eight storey over basement, 186 no. bedroom hotel with below ground pool plant equipment, tank room, standby generator and pumping station (Gross Floor Area: c. 12,478sqm). The development includes for hotel uses on the ground floor including a reception area, lounge area, a restaurant, a bar, a lobby, toilet facilities, and back of house rooms. The ground floor also includes an LV switchroom, an MV switchroom, an ESB substation, a transformer/LV switchroom, a public entrance to the spa and spa facilities including a swimming pool, a whirlpool, a sauna/steam room, male and female changing rooms, and storage rooms. The first floor incorporates spa facilities including a treatment room, a studio, a gym, a lobby area, a storage area, 8 no. meeting rooms with associated reception area, an office, toilet facilities and a pantry. The upper floors incorporate 186 no. hotel bedrooms. The development also includes for a green roof, emergency fire escapes, an upgrade to the existing entrance/exit from the Business Park Campus, new guest vehicle entrance from the Business Park Campus to the north of the site, 2 no. new vehicle entrances from the west of the site, 153 no. car parking spaces, 3 no. set down spaces at the main entrance, service entrance layby to the west of the site, 28 no. cycle spaces, electrical vehicle charging spaces, pumping station kiosk, signage, associated landscaping and boundary treatments, and all other site development works and services ancillary to the proposed development

Appeal Details


Appeal Details
Notification Date: 29/03/2022 BP Reference #: 313102-22
Appeal Type: APPLICANT File Forward Date:
Submission Due Date: 25/04/2022 Submission Sent Date:
Appeal Decision: REFUSED Decision Date: 03/01/2024
Withdrawn Date: Dismissed Date:
Reason: