Planning application details ref: 2422 Kildare County Council

100%100% Complete (warning)

Planning Application: 2422 (Kildare County Council )
File Number: 2422
Application Type: PERMISSION Planning Status: APPLICATION FINALISED
Received Date: 19/01/2024 Decision Due Date: 15/12/2024
Validated Date: 19/01/2024 Invalidated Date:
Further Info Requested: 11/03/2024 Further Info Received: 18/11/2024
Withdrawn Date: Extend Date:
Decision Type: Conditional Decision Date: 09/12/2024
Leave to Appeal: Appeal Date:
Commenced Date: Submissions By:

Applicant Details

Applicant name: CMT Transport LTD
Applicant Address:
Phone Number: Fax Number: 25000078
Corresp. Address:

Applicant Details


Proposed Development

Development Description: for construction of a regional distribution warehouse/logistics centre. The proposed main building will have a gross floor area of 3238 sq.m and will have an overall height of 12.8m (from finished floor level to parapet level) with two storey ancillary offices, staff facilities and drivers waiting area located within the main building envelope along with 6 no. loading docks and a level access loading bay located in the warehouse area, internal plant within warehouse, ground level air conditioning units, roof and southern elevation mounted solar panels and back lit elevation signage. Ancillary to the main building a new 6.5m high sprinkler supply storage tank ancillary 3.5m high pumphouse for fire safety is proposed. The proposed development involves the reconfiguration of an existing turning bay with ancillary roadside verge works and road markings, extension of the existing foul sewer and water main public infrastructure, onsite car parking spaces (including disabled spaces and EV spaces) on site cycle parking spaces. The development includes site development and facilitation works including new vehicular entrance, internal drainage infrastructure with connection to existing surface water pipeline, waste and recycling areas, boundary treatments, landscaping, service yards, internal roads, footpaths, lighting, internal gates and fire tender access route
Development Address: Site 11, Kilcullen Business Campus, Kilcullen, Co Kildare
Architect Name: Martin Murphy Location Key: Kilcullen
Electoral Division: Planner: Louise Murphy
Social Housing Exempt: Plan Enforcement #:
IPC Licence Required: No Waste Licence Required: No
Protected Structure: No Protected Structure #:
Development Name:

Proposed Development


Comments

Significant Case Flag: Comments:

Decision

Decision Date: 09/12/2024 Manager Order: DO56237
Decision Type: Conditional Number of Conditions: 32
Grant Date: 28/01/2025 Grant Managers Order #: DO56237
Section 47 Apply?: Part 5 Apply?:
Expiry Date: 27/01/2030
Decision Description: for construction of a regional distribution warehouse/logistics centre. The proposed main building will have a gross floor area of 3238 sq.m and will have an overall height of 12.8m (from finished floor level to parapet level) with two storey ancillary offices, staff facilities and drivers waiting area located within the main building envelope along with 6 no. loading docks and a level access loading bay located in the warehouse area, internal plant within warehouse, ground level air conditioning units, roof and southern elevation mounted solar panels and back lit elevation signage. Ancillary to the main building a new 6.5m high sprinkler supply storage tank ancillary 3.5m high pumphouse for fire safety is proposed. The proposed development involves the reconfiguration of an existing turning bay with ancillary roadside verge works and road markings, extension of the existing foul sewer and water main public infrastructure, onsite car parking spaces (including disabled spaces and EV spaces) on site cycle parking spaces. The development includes site development and facilitation works including new vehicular entrance, internal drainage infrastructure with connection to existing surface water pipeline, waste and recycling areas, boundary treatments, landscaping, service yards, internal roads, footpaths, lighting, internal gates and fire tender access route

Appeal Details


Appeal Details
Notification Date: BP Reference #:
Appeal Type: File Forward Date:
Submission Due Date: Submission Sent Date:
Appeal Decision: Decision Date:
Withdrawn Date: Dismissed Date:
Reason: